5,314 research outputs found

    Monitoring of coastal dunes habitats in Tuscany through the “MONITO-RARE” project

    Get PDF
    “MONITO-RARE” is a project involving Tuscany Region and Universities of Firenze, Siena and Pisa, aimed to improve the knowledge and develop monitoring methodologies for species and habitats included in Natura 2000 Network and considered of community interest, according to Art. 11 and Art. 17 of the Directive 92/43/EEC. Among the habitat of interest (Annex I), coastal sand dune is one of the most threatened by multiple human pressures (1, 2), such as pollution, coastal erosion, effects of global warming, farming practices, urban development, and pressure from tourism (3). As part of this project, was carried out a first year of monitoring of dunal habitats (Natura 200 code 2110, 2120, 2210, 2230, 2240, 2250* and 2260) in five SACs (Special Areas of Conservation) in order to cover different latitudes of Tuscany coast (“Dune litoranee di Torre del Lago/Selva Pisana”, “Tombolo da Castiglion della Pescaia a Marina di Grosseto”, “Dune costiere del Parco dell’Uccellina” and “Duna del Lago di Burano”). The coastal areas to the north and south of Arno basin are very different by climatic, geomorphologic (erosion) and anthropic factors. The northern coast is twice rainy as the southern one. Nevertheless, sand dune habitats are distributed in a fine scale mosaic, not distinguishable through aerial photos and maps. For this reason, we opted for a stratified sampling in three EUNIS habitat types (B1.3, shifting coastal dunes; B1.4, coastal stable dune grassland; B1.6, coastal dune scrub) for psammophilous vegetation. According to Sperandii et al. (4), we recorded these communities by 262 random plots of 2 x 2 m surface in which were surveyed pressures and threats, floristic composition and an estimate of abundance using a percentage cover scale ranging from 1 to 10. Our sampling is congruent with RanVegDunes (GIVD ID EU-IT-020), the first Italian database gathering standardized, randomly-sampled vegetation data in coastal dune environments. We detected significative differences in abundance and species composition between EUNIS habitat types, between SACs, and between habitat types within SACs. In particular, our data shows particular differences between communities of north and south of Tuscany: the northern SACs to Serchio river are heavily impacted by the presence of mass tourism, with bathing establishments, roads and human trampling. From these evidences can be deduced that trails installed within the DUNETOSCA Life Projects and aimed to reduction of tourism impact may be insufficient to reduce anthropic pressures in those contexts and adequate conservation strategies are required. 1) EEA (1999) State and pressures of the marine and coastal Mediterranean Environment. Environmental Issues Series, No. 5, European Environment Agency, Copenhagen 2) Barcelona Convention, Athens (2012) UNEP/MAP 2012. State of the Mediterranean Marine and Coastal Environment https://wedocs.unep.org/bitstream/handle/20.500.11822/364/sommcer_eng.pdf?sequence=4&isAllowed=y 3) Ciccarelli D. (2014) Environmental Management 54, 194–204 4) Sperandii M.G., Prisco I., Stanisci A., Acosta A.T.R. (2017) Phytocoenologia 47, 231–23

    Enough Is Enough? Searching for the Optimal Sample Size to Monitor European Habitats: A Case Study from Coastal Sand Dunes

    Get PDF
    A robust survey method that samples the main characteristics of plant assemblages is needed to assess the conservation status of European habitat in the Natura 2000 network. A measure of variability, called pseudo-multivariate dissimilarity-based standard error (MultSE), was recently proposed for assessing sample-size adequacy in ecological communities. Here, we used it on coastal sand dune systems in three Special Areas of Conservation (SACs) in Tuscany. Our aim was to assess the minimum number of replicates necessary to adequately characterize sand dune environments in terms of differences between habitats and SACs, after a preliminary baseline assessment of plant diversity. Analysis of \u3b1 and \u3b2 diversity indicated that especially between habitats the three SACs protect different plant communities. The study of the MultSE profiles showed that the minimum number of replicates was related to habitat features and varied between 10 and 25 plots. Two-way PERMANOVA and SIMPER analysis on the full and reduced datasets confirmed that SACs and habitats host different plant communities, and that the contribution of the target species remained unchanged even with a reduced sample size. The proposed methodological approach can be used to develop cost-effective monitoring programs and it can be useful for plant ecologists and biodiversity managers for assessing ecosystem health and changes

    Results on Proton-Irradiated 3D Pixel Sensors Interconnected to RD53A Readout ASIC

    Full text link
    Test beam results obtained with 3D pixel sensors bump-bonded to the RD53A prototype readout ASIC are reported. Sensors from FBK (Italy) and IMB-CNM (Spain) have been tested before and after proton-irradiation to an equivalent fluence of about 11 ×\times 101610^{16} neq\text{n}_{\text{eq}} cm−2^{-2} (1 MeV equivalent neutrons). This is the first time that one single collecting electrode fine pitch 3D sensors are irradiated up to such fluence bump-bonded to a fine pitch ASIC. The preliminary analysis of the collected data shows no degradation on the hit detection efficiencies of the tested sensors after high energy proton irradiation, demonstrating the excellent radiation tolerance of the 3D pixel sensors. Thus, they will be excellent candidates for the extreme radiation environment at the innermost layers of the HL-LHC experiments.Comment: Conference Proceedings of VCI2019, 15th Vienna Conference of Instrumentation, February 18-22, 2019, Vienna, Austria. arXiv admin note: text overlap with arXiv:1903.0196

    Colorectal surgery in Italy during the Covid19 outbreak: a survey from the iCral study group

    Get PDF
    Background The COVID19 pandemic had a deep impact on healthcare facilities in Italy, with profound reorganization of surgical activities. The Italian ColoRectal Anastomotic Leakage (iCral) study group collecting 43 Italian surgical centers experienced in colorectal surgery from multiple regions performed a quick survey to make a snapshot of the current situation. Methods A 25-items questionnaire was sent to the 43 principal investigators of the iCral study group, with questions regard- ing qualitative and quantitative aspects of the surgical activity before and after the COVID19 outbreak. Results Two-thirds of the centers were involved in the treatment of COVID19 cases. Intensive care units (ICU) beds were partially or totally reallocated for the treatment of COVID19 cases in 72% of the hospitals. Elective colorectal surgery for malignancy was stopped or delayed in nearly 30% of the centers, with less than 20% of them still scheduling elective colo- rectal resections for frail and comorbid patients needing postoperative ICU care. A significant reduction of the number of colorectal resections during the time span from January to March 2020 was recorded, with significant delay in treatment in more than 50% of the centers. Discussion Our survey confirms that COVID19 outbreak is severely affecting the activity of colorectal surgery centers partici- pating to iCral study group. This could impact the activity of surgical centers for many months after the end of the emergency

    ICG fluorescence imaging in colorectal surgery: a snapshot from the ICRAL study group

    Get PDF
    Background: Fluorescence-guided visualization is a recently proposed technology in colorectal surgery. Possible uses include evaluating perfusion, navigating lymph nodes and searching for hepatic metastases and peritoneal spread. Despite the absence of high-level evidence, this technique has gained considerable popularity among colorectal surgeons due to its significant reliability, safety, ease of use and relatively low cost. However, the actual use of this technique in daily clinical practice has not been reported to date. Methods: This survey was conducted on April 2020 among 44 centers dealing with colorectal diseases and participating in the Italian ColoRectal Anastomotic Leakage (iCral) study group. Surgeons were approximately equally divided based on geographical criteria from multiple Italian regions, with a large proportion based in public (89.1%) and nonacademic (75.7%) centers. They were invited to answer an online survey to snapshot their current behaviors regarding the use of fluorescence-guided visualization in colorectal surgery. Questions regarding technological availability, indications and techniques, personal approaches and feelings were collected in a 23-item questionnaire. Results: Questionnaire replies were received from 37 institutions and partially answered by 8, as this latter group of centers do not implement fluorescence technology (21.6%). Out of the remaining 29 centers (78,4%), fluorescence is utilized in all laparoscopic colorectal resections by 72.4% of surgeons and only for selected cases by the remaining 27.6%, while 62.1% of respondents do not use fluorescence in open surgery (unless the perfusion is macroscopically uncertain with the naked eye, in which case 41.4% of them do). The survey also suggests that there is no agreement on dilution, dosing and timing, as many different practices are adopted based on personal judgment. Only approximately half of the surgeons reported a reduced leak rate with fluorescence perfusion assessment, but 65.5% of them strongly believe that this technique will become a minimum requirement for colorectal surgery in the future. Conclusion: The survey confirms that fluorescence is becoming a widely used technique in colorectal surgery. However, both the indications and methods still vary considerably; furthermore, the surgeons' perceptions of the results are insufficient to consider this technology essential. This survey emphasizes the need for further research to reach recommendations based on solid scientific evidence. Keywords: Colon cancer; Fluorescence guided surgery; ICG; Laparoscopy; Rectal cancer

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    Constraints on the χ_(c1) versus χ_(c2) polarizations in proton-proton collisions at √s = 8 TeV

    Get PDF
    The polarizations of promptly produced χ_(c1) and χ_(c2) mesons are studied using data collected by the CMS experiment at the LHC, in proton-proton collisions at √s=8  TeV. The χ_c states are reconstructed via their radiative decays χ_c → J/ψγ, with the photons being measured through conversions to e⁺e⁻, which allows the two states to be well resolved. The polarizations are measured in the helicity frame, through the analysis of the χ_(c2) to χ_(c1) yield ratio as a function of the polar or azimuthal angle of the positive muon emitted in the J/ψ → μ⁺μ⁻ decay, in three bins of J/ψ transverse momentum. While no differences are seen between the two states in terms of azimuthal decay angle distributions, they are observed to have significantly different polar anisotropies. The measurement favors a scenario where at least one of the two states is strongly polarized along the helicity quantization axis, in agreement with nonrelativistic quantum chromodynamics predictions. This is the first measurement of significantly polarized quarkonia produced at high transverse momentum

    Search for the standard model Higgs boson in the H to ZZ to 2l 2nu channel in pp collisions at sqrt(s) = 7 TeV

    Get PDF
    A search for the standard model Higgs boson in the H to ZZ to 2l 2nu decay channel, where l = e or mu, in pp collisions at a center-of-mass energy of 7 TeV is presented. The data were collected at the LHC, with the CMS detector, and correspond to an integrated luminosity of 4.6 inverse femtobarns. No significant excess is observed above the background expectation, and upper limits are set on the Higgs boson production cross section. The presence of the standard model Higgs boson with a mass in the 270-440 GeV range is excluded at 95% confidence level.Comment: Submitted to JHE
    • …
    corecore